国精产品一区一区三区有限,国产欧美日韩,97热久久免费频精品99,初尝黑人巨砲波多野结衣

PLC企業資訊
    SGMGV-55A(5.5kW)+SGDV-470A安川伺服驅動器7Rb
    發布者:上海紀略  發布時間:2018-05-07 13:47:00

    SGMGV-55A(5.5kW)+SGDV-470A安川伺服驅動器7Rb,SGM-01A314安川伺服學習,SGMAH-A5BAA41安川伺服pn200參數,長期供應安川yaskawa伺服,電機,驅動器,大量現貨。

    聯系人:  理(市場部)銷售熱線  手    機:13681665097(微信同號)Q      Q:156201575    話:021-61014535

    RM50CA-20S TM55RZ-H CM600DY-24A RM50CA-20S TM55RZ-M CM600DY-34H RM50CA-24F TM60SA-6 CM600E2Y-34H RM50CA-24S TM90CZ-24 CM600HA-12H RM50HA-10F TM90CZ-2H CM600HA-24A RM50HA-12F TM90CZ-H CM600HA-24E RM50HA-20F TM90CZ-M CM600HA-24H RM50HA-24F TM90DZ-24 CM600HA-28H RM50TC-24 TM90DZ-2H CM600HA-5F RM50TC-2H TM90DZ-H CM600HU-12F RM50TC-H TM90DZ-M CM600HU-12H RM50TC-M TM90DZ-M CM600HU-24F RM600DY-66S TM90EZ-24 CM600HU-24H QM200DY-2H TM90EZ-2H CM75BU-12H QM200DY-2HB TM90EZ-H CM75DU-12F QM200DY-H TM90EZ-M CM75DU-12H QM200HA-24 TM90RZ-24 CM75DU-24F QM200HA-2H TM90RZ-2H CM75DU-24H QM200HA-H TM90RZ-H CM75DY-12H QM200HA-HK TM90RZ-M CM75DY-24H QM200HC-M TM90SA-6 CM75DY-28H QM200HH-H UM100CDY-10 CM75E3U-12H QM20DX-H UM100CDY-9 CM75E3U-24H QM20HA-HB UM150CDY-10 CM75E3Y-24E SGMPH系列 容量(W) 扭距(Nm) 型號 SGMPH-01AAA41+SGDM-01ADA SGMPH-01AAA4C+SGDM-01ADA SGMPH-02AAA41+SGDM-02ADA SGMPH-02AAA4C+SGDM-02ADA SGMPH-04AAA41+SGDM-04ADA SGMPH-04AAA4C+SGDM-04ADA SGMPH-08AAA41+SGDM-08ADA SGMPH-08AAA4C+SGDM-08ADA SGMPH-15AAA41+SGDM-15ADA SGMPH-15AAA4C+SGDM-15ADA 歷史編輯 1915~創業期 1915 年 合資公司安川電機制作所成立 1917 年 股份公司安川電機制作所成立  1930~電動機和控制器 1949年 公司股票在東京、大阪、福岡證券市場上市 1950~電動機及應用 1954年 與德國BBC公司 (Brown.Boueri & Co., Ltd)進行直流機器的相關技術的合作 1957年 行橋工廠成立 1958年 發明DC伺服電機和Minertia電機 公司股票在名古屋證券市場上市  1960~工業用電氣 1961年 與法國SEA公司進行印刷電機的相關技術 小倉工廠成立 1964年 東京工廠成立 1968年 開發硬線NC 1969年 開發了SF6氣體開關裝置的旋轉弧方式 申請登記[機電一體化]商標 中間工廠成立 參數No.0 有*標記的參數,設定后需將電源斷開,再重新接通電源,參數才會生效 安川伺服驅動器的常用故障代碼? A.00?????????絕對值數據錯???????????????絕對值錯誤或沒收到??A.02?????????參數中斷???????????????????用戶參數檢測不到? ?A.04?????????參數設置錯誤???????????????用戶參數設置超出允許值???A.10?????????過流???????????????????????電源變壓器過流? ?A.30?????????再生電路檢查錯誤???????????再生電路檢查錯誤? ?A.31?????????位置錯誤脈沖溢出???????????位置錯誤,脈沖超出參數Cn-1E設定值??A.40?????????主電路電壓錯誤?????????????主電路電壓出錯??A.51?????????過速???????????????????????電機轉速過快? ?A.71?????????過載(大負載)???????????????電機幾秒至幾十秒過載運行??A.72?????????過載(小負載)???????????????電機過載下連續運行? ?A.80?????????絕對值編碼器差錯???????????絕對值編碼器每轉脈沖數出錯ssszxx??f??A.81?????????絕對值編碼器失效???????????絕對值編碼器電源不正常??A.82?????????絕對值編碼器檢測錯誤???????絕對值編碼器檢測不正常??A.83?????????絕對值編碼器電池錯誤???????絕對值編碼器電池電壓不正常??A.84?????????絕對值編碼器數據不對???????絕對值編碼器數據接受不正常? ?A.85?????????絕對值編碼器轉速過高???????電機轉速超過400轉/分后編碼器打開??A.A1?????????過熱???????????????????????驅動器過熱? ?A.B1?????????給定輸入錯誤???????????????伺服驅動器CPU檢測給定信號錯誤??A.C1?????????伺服過運行?????????????????伺服電機(編碼器)失控? ?A.C2?????????編碼器輸出相位錯誤?????????編碼器輸出A、B、C相位出錯??A.C3?????????編碼器A相B相斷路???????????編碼器A相B相沒接??A.C4?????????編碼器C相斷路??????????????編碼器C相沒接??A.F1?????????電源缺相???????????????????主電源一相沒接??A.F3?????????電源失電???????????????????電源被切斷? ?CPF00????????手持傳輸錯誤1??????????????通電5秒后,手持與連接仍不對??CPF01????????手持傳輸錯誤2??????????????傳輸發生5次以上錯誤??A.99?????????無錯誤?????????????????????操作狀態不正常???? ?????安川伺服報警代碼??? 報警代碼????????報警名稱????????????????????????主要內容???????? A.00?????????絕對值數據錯誤????????????????不能接受絕對值數據或接受的絕對值數據異常?A.02?????????參數破壞??????????????????????用戶常數的“和數校驗”結果異常??A.04?????????用戶常數設定錯誤??????????????設定的“用戶常數”超過設定范圍?A.10?????????電流過大??????????????????????功率晶體管電流過大?A.30?????????測出再生異常??????????????????再生處理回路異常? A.31?????????位置偏差脈沖溢出??????????????位置偏差脈沖超出了用戶常數“溢出(Cn-1E)”的值

    ·未連接內置的再生制動電阻或再生制動選件 ·高頻度或連續再生制動運行使再生電流超過了內置再生制動電阻或再生制動選件的允許值 MODEL MR-H3CBL1M MR-RB31 MR-RB34 MR-RB51 MR-RB54 MR-HDP01 MR-DP60 MR-DS60 MR-DSCBL25 MR-DSCBL3M-G MR-HTBL05M MR-HTBL1M MR-TB50 MRZJW3-MOTSZ41 MRZJW3-SETUP41 MRZJW3-SETUP51 MR-PWCNS3 HA-FH053 HA-FH13 HA-FH23 HA-FH33 HA-FH43 HA-FH63 ·內置再生制動電阻或再生制動選件的容量不足

    SGMSH-20ACA21安川伺服絕對值編碼器,SGMGV-55ADA61+SGDV-470A01A安川sgds伺服說明書,SGMGV-55A(5.5kW)+SGDV-470A安川伺服驅動器7Rb。

    版權聲明PLC信息網轉載作品均注明出處,本網未注明出處和轉載的,是出于傳遞更多信息之目的,并不意味 著贊同其觀點或證實其內容的真實性。如轉載作品侵犯作者署名權,或有其他諸如版權、肖像權、知識產權等方面的傷害,并非本網故意為之,在接到相關權利人通知后將立即加以更正。聯系電話:0571-87774297。
最新資訊
    An error occurred on the server when processing the URL. Please contact the system administrator.

    If you are the system administrator please click here to find out more about this error.